รายละเอียด GL840
 
Item Description
Model number GL840-M GL840-WV
Number of analog input channels 20 channels in standard configuration, Expandable up to 200 channels
Number of analog input terminals Up to 10 terminals (20 channels / terminal), standard config: 1
Type of analog input terminal Multi-input type, Withstand-voltage type
Port for digital sensor 1 port for the sensor/input terminal/adapter of the GL100
External input/
output *1
Input *2 Trigger or Sampling (1 channel), Logic/Pulse (4 channels)
Output *3 Alarm (4 channels)
Sampling interval 10 ms to 1 hour (10ms to 50ms: voltage only) *4, External signal
Time scale of waveform display 1 sec. to 24 hour /division
Trigger,
Alarm function
Trigger action Start or stop capturing data by the trigger
Repeat action Off, On (auto rearmed)
Trigger source Start: Off, Measured signal, Alarm, External, Clock, Week or Time
Stop: Off, Measured signal, Alarm, External, Clock, Week or Time
Condition Setting Combination: OR or AND
Analog signal: Rising (High), Falling (Low), Window-in, Window-out
Logic signal: Pattern (combination of each input signal in high or low)
Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out
Alarm output Outputs a signal when alarm condition occurs in the input signal *5
Pulse input
function
Rotation count
(RPM) mode
Counts the number of pulses per sampling interval and converts to rpm
(rotations per minute), Number of pulses for one rotation can be set to
50, 500, 5000, 50k, 500k, 5M, 50M, 500M rpm/F.S. (rpm./Full Scale)
Accumulating
count mode
Accumulates the number of pulses from the start of measurement
50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale)
Instant count
mode
Counts the number of pulses per sampling interval
50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale)
Maximum number of pulse inputs Maximum input frequency : 50kHz
Maximum number of count : 50kC/sampling (16-bit counter)
Calculation
function
Between channels Addition, Subtraction, Multiplication, and Division for analog input
Statistical Select two calculations from Average, Peak, Maximum, Minimum, RMS
Search function Search for analog signal levels, values of logic or pulse or alarm point
in captured data
Interface to PC Ethernet (10 BASE-T/100 BASE-TX), USB (Hi-speed), WLAN (using B-568 option)
Storage
device
Internal Built-in 4GB Flash Memory *6
External One SD card slot (Support SDHC memory card, up to 32GB) *7
Saved contents Captured data, Setting conditions, Screen copy
Back up recording data function Backup interval *8 Off, 1, 2, 6, 12, 24 hour(s)
Backup file destination *8 SD memory card or FTP server
Data format *8 GBD (binary) or CSV (test)
Check-sum function (Verifies data file) OFF: Not adding check-sum code to data file.
ON: Adding check-sum code to data file. Check-sum code is verified when replaying data on the GL unit or GL-Connection software.
Capturing mode Mode: Normal, Ring, Relay
Ring: Saves most recent data (Number of capturing data: 1000 to 2000000 points) *9
Relay: Saves data to multiple files without losing data until dada capturing is stopped
Replay data Replays captured data that was saved in the GL840 (in GBD or CSV format)
Scaling (Engineering unit) function Measured value can be converted to specified engineering unit
• Analog voltage: Converts using four reference points (gain, offset)
• Temperature: Converts using two reference points (offset)
• Pulse count: Converts using two reference points (gain)
Action during data capture • Displaying past data (using dual display mode (Current + Past data))
• Hot-swapping the SD memory card
• Saving data in between cursors
Display Size 7-inch TFT color LCD (WVGA: 800 x 480 dots)
Language English, French, German, Chinese, Korean, Russian, Spanish, Japanese
Information *10 Waveform in Y-T with digital values, Waveform only, Digital value, Digital values
and statistics values
Operating environment 0 to 45 ºC, 5 to 85 % RH (non condensed)
(When operating with battery pack 0 to 40 ºC, charging battery 15 to 35 ºC)
Power source AC adapter 100 to 240 V AC, 50/60 Hz (1 pc of adapter is attached as standard accessory)
DC power 8.5 to 24 V DC (DC drive cable (option B-514) is required)
Battery pack Mountable two battery packs (battery pack (option B-569): 7.2V DC, 2900mAh)
Power consumption *11 Max. 38 VA
External dimensions (W x D x H
in mm, Excluding projections)
Approx. 246 x 161 x 58.2 (with the cover) Approx. 246 x 170.4 x 58.2 (with the cover)
Weight *12 Approx. 1218 g (the cover is attached) Approx. 1244 g (the cover is attached)
*1
Input/Output cable for GL (option B-513) is required to connect the signal.
*2
Input signal;
  • Voltage range: Up to 24V (common ground)
  • Signal type: Voltage, Open collector, Contact (relay)
  • Threshold: Approx. + 2.5 V (Hysteresis: Approx. 0.5V (2.5V to 3V))
*3
Output signal: Open collector (pull-up to 5V by 10kΩ resistor)
<Maximum rating of the output transistor>
  • Voltage: Max. 30V,
  • Current: Max. 0.5A,
  • Collector dissipation: Max. 0.2W
*4
Minimum interval varies by number of channels used.
*5
Output port can be specified in each input channel.
*6
The built-in Flash memory is available for units with serial numbers C604XXXX or later. Please contact your local representative for more information.
*7
SD memory card cannot be used on the SD card slot while the wireless LAN unit (opton B-568) is used.
*8
- When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
- When there are meany number of active channels, the sampling time is fast, or the backup interval is long, it may take time to closing the data file after recording stops because the size of the data to be backed up becomes large.
- When saving file to FTP server using wireless LAN connection, backup may fail depending on the communication condition.
- Available sampling speed is the 100 ms or slower when using the CSV format.
- When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
*9
Size of the capture data will be limited to 1/3 of available memory.
*10
Display mode is switched every time the dedicated key is pressed. In magnified digital value mode, the
displayed channel number can be specified. In the waveform display mode, the changing of the time scale will
be effective from the point of the next displayed data.
*11
Rating under maximum power consumption using the AC adapter, with LCD display on, and battery pack(s)
being charged.
*12
Excludes AC adapter and battery pack.
f t g